Quality chainlink fencing in Kenya is about more than the price per roll. Wire diameter, galvanising quality, mesh aperture, roll length and manufacturing consistency all influence how well a fence performs over time—and each of these can be measured, calculated and verified before you pay.
When purchasing chainlink fencing, the lowest price per roll is tempting. For homeowners, contractors, farmers, property developers and institutions, reducing the initial fencing budget can seem like a sensible decision.
But consider what happens when the mesh begins to rust prematurely, stretches out of shape, breaks at tension points or requires replacement sooner than expected. The initial saving can disappear through repairs, replacement materials, additional labour and disruption to the property.
This guide explains how to identify poor-quality chainlink, choose the right corrosion protection, and calculate the real cost of fencing for projects across Kenya—using formulas you can apply on site.
Quick Answer: What Makes Quality Chainlink Fencing?
Quality chainlink fencing should have:
- A clearly stated steel wire diameter in millimetres.
- A galvanised coating appropriate to the intended exposure.
- A suitable mesh aperture for the required security level.
- Uniform weaving and consistently formed diamond openings.
- Secure, consistent twists and finished edges.
- A clearly specified roll length and fence height.
- Appropriate PVC coating where an additional protective and decorative finish is required.
- Verifiable product documentation and applicable quality certification.
The most important buying principle is simple: specify the product before comparing quotations.
1. Why Cheap Chainlink Fencing Can Become Expensive
Not all chainlink fencing is manufactured to the same specification. Two rolls can look almost identical while containing different quantities of steel and offering different levels of corrosion protection.
The most common quality problems include undersized wire, inadequate galvanising, poor PVC coating, inconsistent mesh openings and shorter-than-expected roll lengths. Here are six things to check before purchasing—each with a formula for verification.
A. Undersized Chainlink Wire Diameter
Wire diameter is one of the most important factors affecting the strength and rigidity of chainlink fencing. A thicker steel wire generally provides greater cross-sectional area and resistance to deformation than a thinner wire made from comparable steel.
A supplier may describe a product using a gauge number, but buyers should always request the actual diameter in millimetres. Gauge conventions can vary, making millimetres a clearer basis for comparison.
Formula: Cross-Sectional Area of a Wire
For a round wire of diameter d (in mm):
A = (π × d²) ÷ 4 ≈ 0.7854 × d² (mm²)
Formula: Percentage Reduction in Steel Area
To compare a thinner wire (dthin) against a nominal wire (dnominal):
Area reduction (%) = [ 1 − (dthin ÷ dnominal)² ] × 100
Worked Example: 2.5mm vs 2.2mm Wire
- For a 2.5mm wire:A2.5 = (π × 2.5²) ÷ 4 = 4.909 mm²
- For a 2.2mm wire:A2.2 = (π × 2.2²) ÷ 4 = 3.801 mm²
- Percentage reduction:[ 1 − (2.2 ÷ 2.5)² ] × 100 = [ 1 − 0.7744 ] × 100 = 22.56%
Result: The 2.2mm wire has approximately 22.56% less steel cross-sectional area than the 2.5mm wire—despite the diameter differing by only 0.3mm.
Formula: Wire Mass Per Metre
To calculate the mass of a single wire per metre (assuming steel density ρ = 7,850 kg/m³):
m = A × ρ = [ (π × d²) ÷ 4 ] × 10−6 × 7,850 (kg/m)
Simplified:
m ≈ 0.006165 × d² (kg/m, with d in mm)
- For 2.5mm wire: m ≈ 0.006165 × 6.25 = 0.0385 kg/m
- For 2.2mm wire: m ≈ 0.006165 × 4.84 = 0.0298 kg/m
The 2.2mm wire uses 22.6% less steel per metre. On a 100-metre fence with multiple wires per metre of mesh, this shortfall compounds rapidly.
What to do: Ask for the actual steel core diameter in millimetres. Use a calibrated micrometer to check a sample before accepting bulk delivery. For PVC-coated chainlink, measure the steel core separately from the outside PVC diameter.
B. Inadequate or Misrepresented Galvanising
Galvanising protects steel against corrosion by applying a zinc coating. The zinc corrodes preferentially, protecting the underlying steel. The level of protection depends on the coating specification, coating quality and environmental exposure.
Two commonly encountered processes are:
- Electro-galvanising applies zinc using an electrolytic process. It can produce a relatively smooth finish, but coating weights are typically low—often in the range of 5–25 g/m²—and may not be suitable for outdoor fencing in aggressive environments.
- Hot-dip galvanising immerses the steel wire in molten zinc, forming a metallurgically bonded coating. Coating weights can reach 100–240+ g/m² or higher depending on specification, providing years of active service life.
Formula: Zinc Coating Mass and Equivalent Thickness
Zinc coating mass is typically expressed in grams per square metre of wire surface (g/m²). To convert coating mass to equivalent zinc thickness:
tZn = MZn ÷ ρZn (microns)
Where:
- MZn = zinc coating mass in g/m²
- ρZn = density of zinc = 7,140 kg/m³ = 7.14 g/cm³
Simplified for microns:
tZn (μm) = MZn (g/m²) ÷ 7.14
Worked Example:
| Zinc coating mass | Equivalent zinc thickness |
|---|---|
| 20 g/m² (electro-galvanised) | 20 ÷ 7.14 = 2.8 μm |
| 120 g/m² (standard hot-dip) | 120 ÷ 7.14 = 16.8 μm |
| 240 g/m² (heavy hot-dip) | 240 ÷ 7.14 = 33.6 μm |
| 275 g/m² (coastal grade) | 275 ÷ 7.14 = 38.5 μm |
Formula: Estimated Zinc Coating Life
A common engineering approximation for zinc coating life in outdoor environments (based on corrosion rate r in g/m²/year):
L = MZn ÷ r (years)
Where r depends on environment:
- Rural/inland: ~5–10 g/m²/year
- Urban/industrial: ~10–20 g/m²/year
- Coastal/marine: ~20–40 g/m²/year
Worked Example (Coastal, r = 25 g/m²/year):
- 20 g/m² coating: L = 20 ÷ 25 = 0.8 years
- 120 g/m² coating: L = 120 ÷ 25 = 4.8 years
- 240 g/m² coating: L = 240 ÷ 25 = 9.6 years
- 275 g/m² coating: L = 275 ÷ 25 = 11 years
These are approximations for illustration. Actual service life depends on coating quality, installation, maintenance and specific site conditions.
What to do: Ask your supplier:
- Is the wire hot-dip galvanised or electro-galvanised?
- What zinc coating mass (g/m²) or coating class is specified?
- Which product standard applies?
- Can the supplier provide supporting test documentation?
Do not assume that every product described as galvanised has the same level of protection. A bright, shiny appearance is not proof of adequate zinc coating.
C. Poor-Quality PVC-Coated Chainlink
PVC-coated chainlink combines a polymer outer layer with a steel wire core. A quality product should have a clearly specified steel core, a suitable underlying corrosion-protection system and a consistent polymer coating.
Formula: Core Diameter from Finished Diameter
For PVC-coated wire, the finished outside diameter Dtotal is:
Dtotal = dcore + (2 × tPVC)
Where:
- dcore = steel core diameter (mm)
- tPVC = PVC coating thickness on one side (mm)
Rearranged to find core diameter:
dcore = Dtotal − (2 × tPVC)
Worked Example:
A PVC-coated wire measures 3.0mm outside diameter. The supplier claims 0.5mm PVC thickness. What is the core diameter?
dcore = 3.0 − (2 × 0.5) = 2.0 mm
If the PVC thickness is actually 0.65mm (not uncommon in cheap products), the core is:
dcore = 3.0 − (2 × 0.65) = 1.7 mm
A 1.7mm core has only 72% of the steel area of a 2.0mm core:
(1.7 ÷ 2.0)² = 0.7225 → 27.75% less steel
This is why measuring only the outside diameter is misleading. The same 3.0mm finished wire can contain a 2.0mm core or a 1.7mm core depending on the PVC thickness.
What to do: Request both the steel core diameter and the finished PVC-coated diameter. Confirm the galvanising specification of the core, PVC coating thickness, coating quality and intended outdoor exposure.
D. Short Roll Length
Roll length directly affects the amount of fencing you receive and the actual cost per metre.
Formula: Cost Per Metre
Cost per metre = Price per roll ÷ Actual roll length (m)
Worked Example:
| Specification | Roll A | Roll B |
|---|---|---|
| Price per roll | KSh 6,000 | KSh 5,500 |
| Actual roll length | 18 m | 15 m |
| Cost per metre | 6,000 ÷ 18 = KSh 333.33 | 5,500 ÷ 15 = KSh 366.67 |
Although Roll B costs less per roll, it is 10% more expensive per metre:
[ (366.67 − 333.33) ÷ 333.33 ] × 100 = 10.0%
Formula: Shortfall Percentage
If a roll is sold as length Lnominal but delivers Lactual:
Shortfall (%) = [ (Lnominal − Lactual) ÷ Lnominal ] × 100
For 18m nominal and 15m actual:
[ (18 − 15) ÷ 18 ] × 100 = 16.67% shortfall
You paid for 18 metres and received 15. That is a 16.67% shortfall in material—and a corresponding increase in your effective cost per metre.
What to do: Confirm the roll length in writing. Check a sample roll by measuring the actual mesh length and verify the agreed tolerance before accepting bulk delivery.
E. Incorrect Mesh Aperture
Mesh aperture refers to the size of the openings in the chainlink. The appropriate aperture depends on the intended application, security requirements and project specification.
Commonly encountered chainlink apertures include:
- 50 mm × 50 mm (standard security)
- 65 mm × 65 mm
- 80 mm × 80 mm
- 90 mm × 90 mm (often sold as "chainlink" but unsuitable for security)
Formula: Open Area Percentage
For a square mesh with aperture a (mm) and wire diameter d (mm), the open area percentage is:
Open area (%) = [ a ÷ (a + d) ]² × 100
- Worked Example (50mm aperture, 2.5mm wire):[ 50 ÷ (50 + 2.5) ]² × 100 = (50 ÷ 52.5)² × 100 = 90.7%
- Worked Example (90mm aperture, 2.0mm wire):[ 90 ÷ (90 + 2.0) ]² × 100 = (90 ÷ 92)² × 100 = 95.7%
The larger aperture has more open area—and less steel per square metre. More importantly, a 90mm opening allows a hand or foot to pass through, defeating the security purpose of the fence.
Formula: Steel Mass Per Square Metre of Mesh
For a square mesh, the mass of wire per square metre can be approximated by:
mmesh ≈ (2 × A × ρ) ÷ (a + d) (kg/m²)
Where:
- A = cross-sectional area of one wire (mm²)
- ρ = steel density (7,850 kg/m³ = 7.85 × 10−6 kg/mm³)
- a = aperture (mm)
- d = wire diameter (mm)
- The factor 2 accounts for wires running in both directions
Simplified:
mmesh ≈ [ (2 × 0.7854 × d² × 7.85 × 10−6) ÷ (a + d) ] × 106 (kg/m²)
Which reduces to:
mmesh ≈ (0.01233 × d²) ÷ (a + d) (kg/m²)
- Worked Example (50mm aperture, 2.5mm wire):m ≈ (0.01233 × 6.25) ÷ 52.5 = 0.00147 × 1,000 = 1.47 kg/m²
- Worked Example (90mm aperture, 2.0mm wire):m ≈ (0.01233 × 4.0) ÷ 92 = 0.000536 × 1,000 = 0.536 kg/m²
The 90mm mesh contains approximately 64% less steel per square metre than the 50mm mesh. It is cheaper because it contains less material—and it is less secure because the openings are larger.
What to do: Confirm the mesh aperture in millimetres and check it against the approved project specification. Measure several openings across the roll to identify inconsistent weaving.
F. Inconsistent Weaving and Weak Twists
Chainlink is made by interweaving steel wires to create diamond-shaped openings. Poor manufacturing can produce uneven diamond openings, loose twists, irregular mesh dimensions, poorly finished edges, excessive variation in mesh width and weak points that affect installation and tensioning.
Formula: Mesh Uniformity Check
Measure the aperture at several points across the roll:
Aperture variation (%) = [ (amax − amin) ÷ anominal ] × 100
Worked Example:
Nominal aperture: 50mm
Measured range: 45mm to 58mm
[ (58 − 45) ÷ 50 ] × 100 = 26% variation
A 26% variation indicates inconsistent weaving. This affects installation tension, appearance and the fence's ability to resist cutting and climbing.
What to do: Inspect the mesh across its full width. Check the twists, edges, opening dimensions and general consistency before accepting delivery.
2. Why Corrosion Protection Matters in Coastal Kenya
Coastal Kenya presents particular challenges for outdoor steel fencing. Salt-laden air, humidity and moisture can accelerate corrosion, especially where protective coatings are inadequate or damaged.
For projects in Mombasa, Kilifi, Malindi, Watamu, Diani and Lamu, the corrosion-protection specification should be treated as a major purchasing decision.
However, corrosion is not exclusively a coastal problem. Fencing around Nairobi, Athi River, Thika, Nakuru, Kisumu and Eldoret can also experience corrosion due to rainfall, damp conditions, industrial pollution, soil contact and damage to protective coatings.
Formula: Environmental Corrosivity Adjustment
If a coating is specified for a standard environment but installed in a more aggressive one, the effective life is reduced:
Lactual = Lstandard × (rstandard ÷ ractual)
Where r is the corrosion rate (g/m²/year) of the actual environment.
Worked Example:
A coating rated for 10 years in an inland environment (r = 10 g/m²/year) is installed on the coast (r = 30 g/m²/year):
Lactual = 10 × (10 ÷ 30) = 3.33 years
The same coating that lasts a decade inland may last only a third as long on the coast. This is why coastal projects require a heavier coating specification—not the same product that works in Nairobi.
What to do: For coastal and high-moisture environments, specify a properly hot-dip galvanised product with a coating weight appropriate to marine exposure, or PVC-coated chainlink with a suitable galvanised steel core. For inland residential and agricultural projects, properly specified galvanised chainlink may provide a practical and economical solution.
3. Galvanised vs PVC-Coated Chainlink: Which Should You Choose?
Both galvanised and PVC-coated chainlink have useful applications. The right choice depends on the environment, appearance requirements and project budget.
Hot-Dip Galvanised Chainlink
Hot-dip galvanised chainlink uses a zinc coating to protect the steel wire against corrosion. It is commonly considered for agricultural land, residential plot fencing, commercial property boundaries, industrial premises and general perimeter demarcation.
PVC-Coated Chainlink
PVC-coated chainlink combines a polymer outer layer with a steel wire core. Depending on the product specification, the underlying core may also be galvanised, providing an additional corrosion-protection layer. It is particularly useful for residential estates, schools, sports courts, commercial developments, landscaping projects and coastal applications where the specification is suitable.
Comparison: Galvanised vs PVC-Coated Chainlink
| Feature | Galvanised Chainlink | PVC-Coated Chainlink |
|---|---|---|
| Surface finish | Metallic zinc finish | Coloured polymer finish |
| Corrosion protection | Zinc coating | PVC layer + core protection (if galvanised) |
| Appearance | Industrial and functional | Decorative and visually distinctive |
| Common applications | Farms, boundaries, industrial sites | Estates, schools, sports facilities, landscaping |
| Maintenance | Inspect for coating damage and corrosion | Inspect for cuts, peeling and exposed core |
| Initial cost | Depends on specification | Depends on core wire and coating specification |
Important: PVC-coated chainlink is not automatically better than every galvanised product. A poorly coated PVC product with an inadequate steel core can underperform a properly specified galvanised product. Always compare the core wire and coating specifications.
4. The Real Cost of Cheap Chainlink: Lifecycle Cost vs Purchase Price
The cheapest chainlink roll is not necessarily the cheapest fencing solution. A more useful way to compare products is to consider the total cost of ownership: material purchase, transportation, installation labour, posts and fittings, maintenance, repairs and replacement.
Formula: Total Cost of Ownership (TCO)
TCO = Cmaterial + Cinstallation + Cmaintenance + Creplacement
Formula: Annualised Cost
To compare products with different expected lives:
Annualised cost = TCO ÷ L (KSh/year)
Where L = expected service life in years.
Worked Example: Budget vs Quality Fencing (100m boundary)
| Cost Component | Budget Fencing | Quality Fencing |
|---|---|---|
| Material | KSh 80,000 | KSh 110,000 |
| Installation | KSh 30,000 | KSh 30,000 |
| Initial investment | KSh 110,000 | KSh 140,000 |
| Expected life (coastal) | 3 years | 12 years |
| Replacement cycles in 12 years | 3 (initial + 3 replacements) | 0 |
| Total 12-year cost | 110,000 × 4 = KSh 440,000 | KSh 140,000 |
| Annualised cost | 440,000 ÷ 12 = KSh 36,667 | 140,000 ÷ 12 = KSh 11,667 |
The budget fence costs 3.1 times more per year of service.
36,667 ÷ 11,667 = 3.14
Figures are illustrative and do not represent NRI Steel quotations or predictions of actual service life.
Formula: Break-Even Analysis
If the quality product costs more upfront but lasts longer, the break-even point is:
Break-even (years) = (Cquality − Cbudget) ÷ (Cannual,budget − Cannual,quality)
Where Cannual is the annualised cost of each option.
Using the example above:
Break-even = (140,000 − 110,000) ÷ (36,667 − 11,667) = 30,000 ÷ 25,000 = 1.2 years
The quality fence pays back its premium in approximately 1.2 years through avoided replacement costs.
What to do: Instead of comparing quotations only by roll price, calculate the cost per metre and the annualised cost of ownership. This gives you a realistic comparison between suppliers.
5. Seven Questions to Ask Before Buying Chainlink in Kenya
Before purchasing chainlink for a home, farm, estate, school or industrial facility, ask your supplier these questions.
1. What is the actual steel wire diameter?
Request the diameter in millimetres. For PVC-coated chainlink, ask for the core diameter separately from the finished outside diameter.
2. What is the galvanising process and coating specification?
Confirm whether the wire is hot-dip galvanised or electro-galvanised. Ask for the applicable coating class or zinc coating mass in g/m².
3. What is the mesh aperture?
Confirm whether the product has a 50mm, 65mm, 80mm or another specified opening.
4. What is the actual roll length?
Make sure the quotation states the roll length and applicable tolerance.
5. What is the finished fence height?
Confirm the mesh height in metres, excluding any additional top security arrangements.
6. If the chainlink is PVC-coated, what is the steel core specification?
Do not rely on the finished outside diameter alone. Confirm the core material, core diameter and polymer coating thickness.
7. Can you provide product documentation and certification details?
Request relevant test reports, material specifications and applicable KEBS certification details.
How to Verify a KEBS Standardization Mark
For products carrying a KEBS Standardization Mark, buyers can verify the permit using the methods published by KEBS:
- Visiting the official KEBS website
- Using the official KEBS mobile application
- Sending an SMS in the format
SM#PERMIT NUMBERto 20023 - Calling the KEBS toll-free number 1545
Check that the permit information relates to the product and manufacturer being supplied. A logo or printed mark alone should not replace independent verification.
6. Choosing the Right Chainlink Specification for Your Project
Different projects require different fencing specifications. The correct product should be selected according to the purpose of the fence, site conditions and design requirements.
| Project type | Important specification considerations |
|---|---|
| Residential plot fencing | Wire diameter, mesh aperture, height and corrosion protection |
| Agricultural fencing | Mesh size, wire strength, livestock requirements and exposure |
| Schools and institutions | Security requirements, fence height, durability and visibility |
| Sports facilities | Mesh aperture, finish, safety and appearance |
| Commercial properties | Physical security, wire specification and installation quality |
| Industrial facilities | Heavy-duty wire, structural support and corrosion protection |
| Coastal properties | Appropriate galvanising, PVC coating and maintenance requirements |
7. Why Consider NRI Steel for Chainlink Fencing in Kenya?
NRI Steel manufactures and supplies wire and perimeter security products for residential, commercial, agricultural and industrial applications. Our wire-products range includes galvanised and PVC-coated chainlink, alongside other fencing and security solutions.
We understand that fencing buyers need more than a price per roll. They need to know what they are purchasing, how it will be used and whether the specifications are suitable for their project.
When evaluating chainlink, we encourage buyers to consider:
- Actual steel wire diameter
- Mesh aperture and fence height
- Roll length
- Galvanising and coating specifications
- PVC core and finished diameter, where applicable
- Consistency of weaving and finish
- Product documentation and delivery requirements
Explore our products and technical information:
- Galvanised Chainlink and Barbed Wire
- PVC-Coated Chainlink Fencing
- NRI Steel Fencing Products in Kenya
- NRI Steel Frequently Asked Questions
For a project-specific quotation, provide the required fence height, total perimeter length, mesh aperture, wire diameter, coating preference and delivery location.
8. How to Inspect Chainlink Before Accepting Delivery
Do not wait until installation is complete to discover that the supplied mesh does not match the quotation. Use this practical inspection checklist when receiving chainlink.
Chainlink Delivery Inspection Checklist
- [ ] Confirm the product type: galvanised or PVC-coated.
- [ ] Confirm the steel core diameter in millimetres.
- [ ] For PVC-coated products, measure the core and finished outside diameter separately.
- [ ] Confirm the mesh aperture.
- [ ] Confirm the roll length.
- [ ] Confirm the roll height.
- [ ] Inspect the galvanised coating for visible defects.
- [ ] Inspect PVC coating for cracks, peeling and exposed steel.
- [ ] Check that the mesh openings are consistent.
- [ ] Inspect twists and finished edges.
- [ ] Compare the delivered product against the purchase order.
- [ ] Retain delivery notes and relevant product documentation.
For large projects, agree on sampling and acceptance procedures before delivery. Where compliance is disputed, use appropriate calibrated measuring instruments and laboratory testing rather than relying on visual inspection alone.
Frequently Asked Questions About Chainlink Fencing in Kenya
1. What is the best chainlink fencing in Kenya?
The best chainlink depends on the application, site exposure, security requirements and budget. A quality product should have a clearly stated wire diameter, suitable galvanising, consistent mesh openings and a specified roll length.
2. Why does cheap chainlink rust quickly?
The most common cause is inadequate zinc coating—either electro-galvanised wire sold as hot-dip, or hot-dip with insufficient coating weight for the environment. Physical damage during installation and aggressive environmental exposure accelerate the process. Using the coating life formula L = MZn ÷ r, a 20 g/m² coating in a coastal environment (r = 25 g/m²/year) has an estimated life of less than one year.
3. Is PVC-coated chainlink better than galvanised chainlink?
PVC-coated chainlink provides an additional polymer layer, but its performance also depends on the quality of the underlying steel and metallic corrosion protection. A PVC jacket over bare steel is not equivalent to PVC over hot-dip galvanised wire.
4. Is hot-dip galvanised chainlink suitable for coastal Kenya?
It can be suitable when the galvanising specification is selected for the actual marine exposure. More aggressive environments may require enhanced protection, such as a heavier coating weight or PVC over a galvanised core.
5. How long should chainlink fencing last?
There is no universal service-life figure. Durability depends on wire dimensions, coating specifications, environmental exposure, installation and maintenance. The coating life formula L = MZn ÷ r provides an engineering estimate when the coating mass and environmental corrosion rate are known.
6. What is the best chainlink wire diameter?
The correct diameter depends on the project, required mechanical performance, security needs and applicable specification. For security fencing, 2.0mm (14G) is the practical minimum; 2.5mm (12.5G) is appropriate for high-security and industrial applications. Always confirm the actual diameter in millimetres.
7. What should I compare when buying chainlink?
Compare wire diameter in millimetres, mesh aperture, zinc coating mass in g/m², PVC coating thickness and core specification where applicable, actual roll length, manufacturing quality, documentation and total installed cost. Use the cost-per-metre formula to normalise quotations of different roll lengths.
8. How do I calculate the cost per metre of chainlink?
Cost per metre = Price per roll ÷ Actual roll length (m)
Always use the actual roll length, not the nominal length on the label.
9. How do I calculate the steel area difference between two wire gauges?
Area reduction (%) = [ 1 − (dthin ÷ dnominal)² ] × 100
For example, a 2.2mm wire versus a 2.5mm wire has 22.56% less steel area.
Conclusion: Buy for Durability, Not Just the Lowest Price
Cheap chainlink may appear attractive when preparing a construction budget, but the initial purchase price does not tell the whole story. A durable fencing solution begins with the correct wire dimensions, appropriate corrosion protection, consistent manufacturing and proper installation.
For Kenyan contractors, property developers, institutions and homeowners, these considerations are especially important when fencing properties exposed to demanding environmental conditions. Use the formulas in this guide to verify what you are buying:
- Cross-sectional area: A = (π × d²) ÷ 4
- Area reduction: [ 1 − (dthin ÷ dnominal)² ] × 100%
- Zinc thickness: tZn (μm) = MZn ÷ 7.14
- Coating life: L = MZn ÷ r
- Cost per metre: Price per roll ÷ actual roll length
- Annualised cost: TCO ÷ expected life
Choose chainlink based on specifications. Protect your investment through quality.